It is lucrative to save pump energy cost for a water distribution system. There are many approaches to achieve the goal of energy cost saving. One of the effective means is to optimally schedule the pump operation. A solution methodology has been developed for optimizing pump scheduling while satisfying system operation criteria. Pump operation is optimized by applying a competent genetic algorithm. This paper demonstrates a case study that is conducted for a benchmark example previously studied by using conventional nonlinear optimization technique and simulated annealing. The study shows that the great cost saving can be achieved by performing pump operation optimization. The results obtained in this paper are compared to the previous study. It illustrates that the pump optimization model, based upon the competent genetic algorithm, outperforms the previously developed methods.
机译:利用水分配系统节省泵能量成本。有许多方法来实现能源成本节约的目标。其中一个有效手段是最佳地安排泵操作。已经开发了一种解决方法,用于优化泵调度,同时满足系统操作标准。通过应用主管遗传算法优化泵操作。本文演示了通过使用传统的非线性优化技术和模拟退火的先前研究先前研究的基准示例的案例研究。该研究表明,通过执行泵运行优化可以实现巨大的成本节省。本文获得的结果与先前的研究进行了比较。它说明了泵优化模型,基于主管遗传算法,优于先前开发的方法。