Centre for Advanced Technology is developing its second synchrotron radiation source INDUS-2 which is a 2.5 GeV electron storage ring. Dipole vacuum chambers are the vital components of Indus-2 vacuum system. Each of these chambers is approx. 3.6 m long and 0.67 m wide with 24 nos. of ports of various sizes. The dipole chambers were made by machining two halves and they are then lip welded together. The dipole chamber has approx. 14 m of total weld length and it was leak tested for leak tightness of the order of 10-10 mbar l/s. Helium mass spectrometer leak detector (HMSLD) was utilized for the leak testing. Subsequently the leaks of various orders in welding joints were repaired and leak tightness achieved. This paper describes the experiences during leak testing of 20 nos. of Aluminum dipole chambers for INDUS-2.
机译:先进技术中心正在开发其第二同步辐射源INDUS-2,即2.5 GEV电子存储环。偶极真空室是INDUS-2真空系统的重要组成部分。这些腔室中的每一个约为。 3.6米长,0.67米宽,24号。各种尺寸的港口。偶极室通过加工两半而制成,然后润唇一起焊接在一起。偶极室具有约。总焊接长度的14米,泄漏测试的泄漏紧密性为10-10毫巴L / s。利用氦质谱仪泄漏检测器(HMSLD)进行泄漏测试。随后,修复了焊接接头中各种订单的泄漏并达到泄漏性。本文介绍了20个NOS泄漏测试期间的经验。铝偶极室的茚 - 2。