首页> 外文会议>Annual international conference on incineration and thermal treatment technologies >DEMONSTRATION OF MERCURY CAPTURE EFFICIENCY DURING MEDICAL WASTE PROCESSING IN A PEM?
【24h】

DEMONSTRATION OF MERCURY CAPTURE EFFICIENCY DURING MEDICAL WASTE PROCESSING IN A PEM?

机译:在PEM中医疗废物处理过程中汞捕获效率的示范?

获取原文

摘要

Medical waste has historically contained mercury which escaped to the environment during incineration. In 1997, EPA enacted strict regulations on mercury and other emissions which resulted in closure of about 90% of the medical waste incinerators. As an alternative to incineration, IET has developed a plasma based gasification system for medical waste processing. One of the design criteria was to eliminate or at least minimize mercury release from the system. This paper presents the results of a series of three tests on mercury emissions where the release was shown to be well below EPA regulatory criteria. Two of the three tests on the system offgas were below the EPA Method 29 detection limit.
机译:医疗废物在历史上含有汞,在焚烧过程中逃离环境。 1997年,EPA颁布了严格的汞和其他排放法规,这些排放量为约90%的医疗废物焚烧炉。作为焚烧的替代方案,IET开发了一种用于医疗废物处理的基于等离子体的气化系统。其中一个设计标准是消除或至少从系统中释放汞释放。本文介绍了一系列三次对汞排放测试的结果,其中释放的释放得到远低于EPA监管标准。系统OFFGA的三种测试中的两个低于EPA方法29检测限。