An estimator identifying the flow rate through a rotary blood pump was developed. This estimation algorithm uses the pump current and speed signals to estimate the blood flow rate through the pump. The algorithm was derived based on the force balancebetween the electric torque generated by the motor and the load torque, including the mechanical losses. The corresponding estimator parameters were identified using experimental data in the laboratory. The estimator performed well in mock circulatory loop experiments simulating different physiologic conditions. This algorithm will be implemented in a single board computer to estimate the flow rate of the rotary pump in an implantable left ventricular assist device without invasive sensors.
机译:开发了通过旋转血液泵识别流速的估计器。该估计算法使用泵电流和速度信号来估计通过泵的血液流速。该算法基于电动机和负载扭矩产生的电动扭矩和包括机械损耗的力余额来导出。使用实验室中的实验数据识别相应的估计器参数。估计器在模拟不同生理条件的模拟循环回路实验中表现良好。该算法将在单板计算机中实现,以估计在没有侵入式传感器的可植入左心室辅助装置中的旋转泵的流量。