摘要

Bayon temple, Angkor Tom in Cambodia is one of the most significant monuments in Angkor monuments in terms of Khmer culture. The main tower of Bayon is 31 m high tower structure of sandstones by the dry masonry. The top area of main tower has a risk of collapses of constructed stones by proceeding of new cracks and joints between stones. Now, the repairs are severely damaged, and second repairing should be necessary. In this paper, we apply NMM-DDA, which is one of the numerical analysis techniques for discontinuous model using the principle of minimum total potential energy and penalty method. And, we conduct a numerical analysis of the top area of Bayon main tower to assess the safety level of masonry construction with the cracks. The analysis model of masonry construction and position of cracks is based on the measurement and drawings at the sites. In addition to the analysis, we also examined about the method of a new reinforcement by NMM-DDA.
机译:Bayon Temple,柬埔寨吴哥汤姆是高棉文化方面最重要的吴哥纪念碑之一。 Bayon的主塔是干燥的砌体31米的砂岩高塔架结构。主塔的顶部区域通过在石头之间的新裂缝和关节进行新的裂缝和关节,具有构造的石头的风险。现在,维修受到严重损坏,应该需要第二次修复。在本文中,我们应用NMM-DDA,这是使用最小总势能和惩罚方法的原理的不连续模型的数值分析技术之一。而且,我们对Bayon主塔的顶部区域进行了数值分析,以评估裂缝结构的砌体结构的安全水平。砌体结构的分析模型和裂缝位置基于位点的测量和图纸。除了分析外,我们还通过NMM-DDA检查了新加固的方法。