Sandia National Laboratories in Albuquerque, New Mexico (SNL/NM), operates a Corrective Action Management Unit (CAMU) for the United States Department of Energy (DOE). In 1997 SNL/NM was granted a permit modification that allowed construction and operation of a CAMU. The CAMU follows regulatory guidance that facilitates expedient and cost-effective cleanup and management of hazardous remediation wastes. Treatment operations were completed in January 2003 in conjunction with containment of 845,000 cubic feet (23,930 cubic meters) of treated soil. The containment cell is situated approximately 485 feet (148 meters) above groundwater in a semiarid region marked by low rainfall and high evapotransporation. These site conditions required a unique approach to monitoring the containment cell performance and ultimately protecting groundwater. To satisfy Resource Conservation and Recovery Act groundwater monitoring requirements, a Vadose Zone Monitoring System (VZMS) for rapidly detecting leaks was incorporated into the containment cell design. One component of the VZMS, the Primary Subliner (PSL) monitoring system, utilizes the containment cell subliner to focus potential leakage into five longitudinal trenches. Each trench contains a wicking material and a vitrified clay pipe used to provide access for a neutron probe to measure soil moisture content directly under the containment cell. The other component of the VZMS, the Vertical Sensor Array (VSA), consists of 22 time-domain reflectometers that provide a backup to the PSL.
机译:新墨西哥州阿尔伯克基(SNL / NM)的Sandia National Laboratories,为美国能源部(DOE)提供了纠正措施管理单元(CAMU)。 1997年,SNL / NM被授予许可修改,允许CAMU的建设和运营。 CAMU遵循规范指导,促进了有利,经济效益的清理和管理危险修复废物。治疗业务于2003年1月完成,遏制845,000立方英尺(23,930立方米)处理的土壤。容纳电池位于地下水中的约485英尺(148米),在低降雨量和高蒸发程度上标记的半干旱区域中。这些网站条件需要一种独特的方法来监测容器细胞性能和最终保护地下水。为了满足资源保护和恢复动作地下水监测要求,将用于快速检测泄漏的助源区监测系统(VZMS)纳入容纳细胞设计。 VZMS的一个组成部分,主要upbliner(PSL)监测系统,利用遏制细胞upbliner将潜在的泄漏聚焦到五个纵向沟槽中。每个沟槽含有芯吸材料和玻璃化粘土管,用于提供中子探针的通道,以直接在容纳细胞下测量土壤水分含量。 VZMS的其他组件,垂直传感器阵列(VSA)由22个时间域反射计组成,其向PSL提供备份。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号