Spalling is defined as damages to concrete exposed to high temperature during fire, causing cracks and localized bursting of small pieces of concrete. As the concrete strength increases, the degree of damage caused by spalling becomes more serious due to impaired permeability. It has been reported that polypropylene(PP) fiber has an important role in protecting concrete from spalling, and the optimum dosage of PP fiber is 0.2%. However, this result was based on the fire test of non-reinforced concrete specimens. The high-temperature behavior of high-strength reinforced concrete columns with various concrete strength and various quantity of PP fibers is investigated in this study. The results revealed that the ratio of unstressed residual strength of columns increased as the concrete strength increased and as the quantity of PP fiber increased from 0% to 0.2% the residual strength of columns increase. However, the effect of PP fiber quantity on residual strength of column was barely above 0.2%.
机译:剥落被定义为在火灾中暴露在高温的混凝土的损坏,导致小块混凝土的裂缝和局部爆破。随着混凝土强度的增加,由于渗透率受损,剥落引起的损坏程度变得更严重。据报道,聚丙烯(PP)纤维在保护混凝土剥落中具有重要作用,PP纤维的最佳剂量为0.2%。但是,该结果基于非钢筋混凝土试样的火灾试验。本研究研究了具有各种混凝土强度和各种PP纤维的高强度钢筋混凝土柱的高温特性。结果表明,随着混凝土强度的增加,随着PP纤维量增加到0.2%的柱子增加,柱子量增加的柱子的残余强度的比例增加。然而,PP纤维量对塔的残余强度的影响几乎没有高于0.2%。