首页> 外文会议>International conference on building physics >The effect of deflection of double glazing panes on sound insulation and heat transfer
【24h】

The effect of deflection of double glazing panes on sound insulation and heat transfer

机译:双层玻璃窗对隔音和热传递的影响

获取原文

摘要

The objectives of this study are to investigate the influence of deflection of a sealed double glazing panes on the sound and thermal performance. Acoustic measurements have been performed between sound transmission rooms. According to this investigation it has been determined that the weighted sound reduction index R_w changes within 1dB. In order to investigate heat transfer through a glass unit, numerical simulation model THERM-5 was used in the analysis and a large-scale glass unit test model has been constructed for this experimental investigation. The experimental investigation has been performed in a climate chamber. According to results extra heat transfer due to deflection of glass unit is insignificant if initial distance between glasses is even through the whole area of a glass unit, but it may rise up as high as 30% at the central part, if the glass unit is made with initial deflection of glass unit panes.
机译:本研究的目标是调查密封双层玻璃窗对声音和热性能的挠度的影响。声音传输室之间已经进行了声学测量。根据这项调查,已经确定加权减速指数R_W在1dB内发生变化。为了通过玻璃单元调查传热,在分析中使用数值模拟模型Therm-5,并为该实验研究构建了大规模的玻璃单元测试模型。实验研究已经在气候室进行。根据玻璃单元的偏转引起的额外传热如果玻璃之间的初始距离甚至通过玻璃单元的整个区域,但如果玻璃单元是玻璃单元的初始距离,则可能在中央部分上升高达30%。用玻璃单元窗格的初始偏转制成。