首页> 外文会议>National Conference on Fluid Power >Pressure Ratings and Design Guidelines for Continuous Cast Ductile Iron in Hydraulic Applications
【24h】

Pressure Ratings and Design Guidelines for Continuous Cast Ductile Iron in Hydraulic Applications

机译:液压应用中连续浇铸铁铁的压力评级和设计指南

获取原文
获取外文期刊封面目录资料

摘要

The methods for determining pressure ratings in components within a hydraulic circuit are defined by NFPA standard T2.6.1, R1-1991. This standard requires 2 separate tests: A burst test to determine the ultimate allowable stress and an impulse test to validate the fatigue strength of a component under cyclical loading. In this study, the pressure rating for continuously cast ductile iron bar stock was determined using the guidelines established in T2.6.1 utilizing test manifold blocks consisting of two drilled ports, one under hydraulic pressure and the other open to the atmosphere. This report contains the results of the pressure rating validation and plotting of the fatigue data for 1045 plain carbon hot rolled steel and ASTM A536 grade 65-45-12 continuous cast ductile iron.
机译:用于确定液压回路内的部件中的压力额定值的方法由NFPA标准T2.6.1,R1-1991限定。本标准需要2个单独的测试:突发测试以确定最终允许的应力和脉冲测试,以验证循环载荷下组分的疲劳强度。在这项研究中,使用T2.6.1中建立的指南确定了连续浇铸延展铁杆股票的压力等级利用由两个钻孔的块,一个在液压和其他对大气中开放的测试歧管块确定。本报告包含1045普通碳热轧钢和ASTM A536级65-45-12连续浇铸韧性的疲劳数据的疲劳数据的结果。