首页> 外文会议>National Conference on Fluid Power >APPLICATION OF A NON-LINEAR MODEL TO A HIGHLY OVERLAPPED ELECTROHYDRAULIC PROPORTIONAL VALVE
【24h】

APPLICATION OF A NON-LINEAR MODEL TO A HIGHLY OVERLAPPED ELECTROHYDRAULIC PROPORTIONAL VALVE

机译:非线性模型在高度重叠电液比例阀中的应用

获取原文
获取外文期刊封面目录资料

摘要

The modeling method put forth by Johnson [2014], a companion paper at this same conference, was applied to a commercially available electrohydraulic proportional valve using a fixed discharge coefficient valve model. This modeling method relies upon externally measured performance data, not internal dimensions or other details. The discussion describes the test procedure, which is essentially the same as that put forth in ISO 10770-1 [2007], the test and tested equipment, and the methods of processing the data. There was one exception to ISO 10770-1: The two work port pressures were recorded during the flow metering test necessitated by high work port pressure loss. Also described are the analytical methods used to synthesize the model parameters from the test results and the procedures for adjusting raw data for imperfect parameter regulation during testing. Then model results are compared directly to the test results with excellent correlations between the two.
机译:Johnson [2014],在同一会议上的伴侣纸上提出的建模方法应用于使用固定放电系数阀模型的市售电液比例阀。该建模方法依赖于外部测量的性能数据,而不是内部尺寸或其他细节。讨论描述了测试程序,其基本上与ISO 10770-1中提出的测试程序,测试和测试设备以及处理数据的方法。 ISO 10770-1有一个例外:在高效港口压力损失所需的流量计量试验期间记录了两项工作港口压力。还描述了用于从测试结果中综合模型参数的分析方法以及用于调整测试期间的不完美参数调节的原始数据的程序。然后将模型结果直接与测试结果进行比较,在两者之间具有出色的相关性。