Federal Aviation Administration (FAA) and Boeing product quality management policies dictate that test measurement calibrations be traceable to a primary standard, and test measurement uncertainties be known and documented. These uncertainties include instrumentation, signal conditioning, software, and test equipment used to collect the test data. The methods and processes to be used to determine and document uncertainties associated with over 20,000 test measurements supporting Boeing Commercial Airplane test programs are presented. Federal Aviation Administration (FAA) Evaluation Criteria 8100.7A and Federal Aviation Requirement (FAR) 21.39 require that all test equipment and test software be calibrated according to approved calibration procedures before the Type Inspection Authorization can be issued for any certification testing [1]. Boeing calibration procedures for test systems [2] call for all significant errors or uncertainties be evaluated and documented for each test measurement. The key topics, applicable to meeting these requirements, described in this paper include: (a) Configuration description of a "typical" complex test system, (b) Uncertainty determination methods and processes selected for end-to-end test system measurements, (c) Equations associated with test measurements and related parameters, (d) Identification of uncertainty contributors associated with test measurements and related parameters, (e) Determination of combined and expanded uncertainty estimates [7,8] for test measurements, and (f) A summary of end-to-end test measurement uncertainty methods and processes for a "typical" test system. These methods and processes have been used successfully to document test measurement uncertainties in order to comply with government and company requirements, and to ensure the consistently high quality of our products.
机译:联邦航空管理局(FAA)和波音产品质量管理政策决定,试验测量校准可追溯到主要标准,并检测测量不确定性是已知和记录的。这些不确定性包括用于收集测试数据的仪器,信号调理,软件和测试设备。提供了用于确定和记录与支持波音商业飞机测试程序的超过20,000个测试测量相关的不确定性的方法和过程。联邦航空管理局(FAA)评估标准8100.7a和联邦航空公司(FAR)21.39要求根据批准的校准程序校准所有测试设备和测试软件,然后才能为任何认证测试发出类型检查授权[1]。用于测试系统的波音校准程序[2]呼叫对每个测试测量进行评估和记录所有重大错误或不确定性的呼叫。本文描述的适用于满足这些要求的关键主题包括:(a)配置描述“典型”复杂测试系统,(b)用于端到端测试系统测量的不确定性确定方法和过程( c)与测试测量和相关参数相关的等式,(d)识别与测试测量和相关参数相关的不确定性贡献者,(e)用于测试测量的组合和扩展的不确定性估计的结合和扩展的不确定性估计,并且(f)a结束测试测量的结束测试测量不确定方法和“典型”测试系统的过程。这些方法和过程已成功用于记录测试测量不确定性,以符合政府和公司的要求,并确保我们的产品始终如一的产品。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号