摘要

A 5,000 MT atmospheric ammonia storage tank, which was originally commissioned in March 1998, needed to be decommissioned and repaired due to the failure of the inner shell of this double walled tank. The causes of the failure, as well as the corrective and preventive actions taken, are discussed.
机译:1998年3月最初委托的5,000吨大气氨储罐需要退役和修复由于该双壁坦克的内壳体的失效。讨论了失败的原因,以及采取的纠正和预防措施。