Power electronics components are protected using power fuses. It is a very well-known phenomenon that fuses for semi-conductors are subjected to thermal fatigue and fuses-manufacturers developed rules for a good determination of the protection. But with new semiconductor-switches, such as IGBTB, the operational frequencies are very high (1 to 20 kHz) and it becomes necessary to understand what happens and to reconsider the behavior of the fuses in order to foresee what will happen in the field. An electrical modeling of power double body fuses is proposed in this article in order to evaluate global current and current density inside these components. The aim is to conclude on the design of these components or on their use in power structures.
机译:使用电源保险丝保护电力电子元件。这是一个非常众所周知的现象,对半导体的保险丝受到热疲劳和保险丝制造商的制定规则,以获得良好的保护。但是,使用新的半导体交换机,例如IGBTB,操作频率非常高(1到20 kHz),有必要了解发生的事情并重新考虑保险丝的行为,以便预见该领域会发生什么。在本文中提出了一种功率双体保险丝的电气建模,以评估这些组件内的全局电流和电流密度。目的是在这些组件的设计或在电力结构中的使用时得出结论。