The AC magnetic testing method of high exciting frequency (60kHz) by using a coaxial probe is proposed to evaluate the Post Weld Heat Treatment (PWHT) temperature, nondestructively. Low alloy steel welded joint specimens (1.25Cr-0.5Mo and 2.25Cr-1Mo) and pipes (1.25Cr-0.5Mo) under several PWHT temperature conditions were investigated. It is found that the normalized 3rd harmonic component intensity (Fh{sub}3) of the detected signals, which is defined as the ratio of the 3rd harmonic component intensity to the fundamental harmonic component intensity, changes considerably with the PWHT temperature. The normalized 3rd harmonic component intensity is related to the pinning strength k in the JA model. The regression curve based on JA model agrees with the experimental results of 1.25Cr-0.5Mo weld joint pipes.
机译:提出了使用同轴探针的高励磁频率(60kHz)的AC磁性测试方法,以评估焊接后热处理(PWHT)温度,无损。低合金钢焊接关节标本(1.25Cr-0.5Mo和2.25cr-1Mo)和管道(1.25cr-0.5mo)在几个pwht温度条件下进行了调查。发现检测信号的归一化的第三谐波分量强度(FH {Sub} 3)定义为3rd谐波分量强度与基本谐波分量强度的比率,随着PWHT温度变化。归一化的第三谐波分量强度与JA模型中的钉扎强度K有关。基于JA Model的回归曲线同意1.25Cr-0.5Mo焊接接头管的实验结果。