AC electromagnetic flowmeters yield a low-frequency signal whose amplitude is proportional to the average fluid velocity. Typically, the signal amplitude can be below 1 mV and suffers a strong interference from the coils that create the driving magnetic field. This paper provides a novel circuit design to amplify and demodulate the voltage picked up by the electrodes and to minimize interference. The amplifier includes a fully differential front end. The demodulation consists of synchronous rectification and sampling with zero-order hold followed by low-pass filtering. The result is a 0.25 mV/(m/s)/mT voltage, insensitive to dc level shifts.
机译:交流电磁流量计产生低频信号,其幅度与平均流体速度成比例。通常,信号幅度可以低于1 mV,并且遭受来自产生驱动磁场的线圈的强烈干扰。本文提供了一种新颖的电路设计,用于放大和解调电极拾取的电压并最小化干扰。放大器包括完全差分前端。解调包括同步整流和使用零阶保持的采样,然后是低通滤波。结果是0.25 mV /(m / s)/ mt电压,对DC电平的差异不敏感。