Electrical treeing tests are performed on XLPE insulation specimens of 110 kV AC cables. The times for electrical trees to initiate under different voltage levels of power frequency are recorded and statistically analyzed. The relationship between the voltage and time is characterized by the classical inverse power law, which is commonly used for the performance evaluation of electrical aging. The time for tree initiation under each voltage level can be determined corresponding to different cumulative probability, and the results show that the voltage endurance coefficient increases along with the increase of tree initiation probability. By the V-t curve method, the coefficient is 13.8 at 99% initiation probability, compared with 10.3 at 63.2%. Moreover, the coefficient is also derived from the relationship between the time of treeing breakdown and the voltage applied, which is 10.1 by residual voltage method, smaller than the value of 13.8 obtained the same way by tree initiation. In this paper, the values of voltage endurance coefficient are in the variation range from 10 to 14, very similar to those obtained by traditional breakdown tests on XLPE cable insulation.
机译:电动树木测试是在110kV AC电缆的XLPE绝缘标本上进行的。记录和统计分析在电力频率的不同电压水平下发起电气树的时间。电压和时间之间的关系的特征在于经典的逆动力法,其通常用于电老化的性能评估。可以确定与不同累积概率相对应确定每个电压电平下树起始的时间,结果表明,随着树起初概率的增加,电压耐久系数随着树的增加而增加。通过V-T曲线方法,系数为99%的引发概率为13.8,与10.3相比为63.2%。此外,系数也来自于树突击穿的时间与施加的电压之间的关系,这是通过剩余电压方法的10.1,小于通过树起始相同的方式获得的值为13.8。在本文中,电压耐久系数的值在变化范围为10至14,非常类似于通过XLPE电缆绝缘的传统击穿测试获得的值。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号