首页> 外文会议>Offshore technology conference >Highly Compliant Rigid Risers: Field Test Benchmarking a Time Domain VIV Algorithm
【24h】

Highly Compliant Rigid Risers: Field Test Benchmarking a Time Domain VIV Algorithm

机译:高度符合的刚性提升管:现场测试基准测试时域VIV算法

获取原文

摘要

This paper presents a time domain procedure for calcualting the Vortex Induced Vibration (VIV) of risers, and compares the computer simulation results with large scale physical test data. The model test data was acquired by the Phase 1 HCR riser JIP. That project conducted large scale model tests of Highly Compliant Rigid Risers in about 800 ft of still water with dynamic vessel heave simulated by a mechanical actuator. Most of the tests exhibited significant intermittent Vortex Induced Vibration (VIV) which impacts in-plane riser response and strength with in-plane drag amplification, and impacts riser fatigue with high frequency VIV bending stress.
机译:本文介绍了计算涡流诱导振动(VIV)的涡流振动(VIV)的时域步骤,并将计算机仿真结果与大规模物理测试数据进行比较。模型测试数据由第1阶段HCR立管jip获取。该项目在大约800英尺的静止水中进行了大规模模型测试,其静止的静止水与机械执行器模拟的动态容器升降。大多数测试表现出显着的间歇性涡旋诱导的振动(VIV),其影响平面内提升板响应和强度与面内阻力扩增,并利用高频VIV弯曲应力影响提升管疲劳。