首页> 外文会议>SOLAR conference >Performance of an AIr-Based Solar Thermal System After Twenty Years of Opertion
【24h】

Performance of an AIr-Based Solar Thermal System After Twenty Years of Opertion

机译:20多年运行后的空气热系统的性能

获取原文

摘要

Investigations of a 20 year old air-based solar installation were made to quantify the degradation of system components as well as operation of the system as a whole. The current solar fractio nfo the system is extremely low at 13 percent. Experiments show a marked degradation in both the transmittance-absorbance product and the loss coefficient of hte collector array. The pebbel beds were also subject to high losses through the building foundation as well as non-uniform flow caused by an obstruction in the upper plenum. The effects of these degradations would lower the solar fraction from an optimum of 44 to 32 percent. The low value for the current performance is attributed to poor sensor placement and the control strategy.
机译:对20岁的空气基太阳能安装的调查量是量化系统成分的降低以及整体系统的运行。目前的太阳能乳突NFO系统极低为13%。实验显示透射率吸收产品和HTE收集器阵列的损耗系数的显着降解。 PEBBEL床也经受建筑基础的高损失,并且在上部增压室中的障碍物引起的不均匀流动。这些降解的效果将降低太阳能级数44%至32%。当前性能的低值归因于传感器放置差和控制策略。

著录项

  • 来源
    《SOLAR conference》|2000年||共6页
  • 会议地点
  • 作者

  • 作者单位
  • 会议组织
  • 原文格式 PDF
  • 正文语种
  • 中图分类 太阳能;
  • 关键词

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号