首页> 外文会议>Topical meeting on the technology of fusion energy >Activation, decay heat, and waste disposal analyses for the aries-at power plant
【24h】

Activation, decay heat, and waste disposal analyses for the aries-at power plant

机译:激活,衰变热量和废水处理分析 - 在发电厂

获取原文

摘要

Detailed activation,decay heat and waste disposal calculations of the ARIES-AT design are performed to evaluate the safety aspects of the device. The high initial activity of the SiC highly irradiated components translates directly into a higher initial decay heat for these structures than for the well-protected steel-based components. However, after a one-hour cool-down period, the SiC decay heat drops by two decades to levels comparable to the steel-based components. The decay heat of the LiPb coolant was found to exceed that of the SiC components for several days after shutdown.
机译:进行详细的激活,衰变热量和废物处理计算的模拟设计,以评估装置的安全方面。 SiC高度照射组件的高初始活性直接转化为这些结构的初始衰减热量,而不是用于良好保护的钢基组分。然而,在一个小时的冷却时间之后,SiC衰变热量将二十多年降至与钢基组件相当的水平。在关闭后,发现LiPB冷却剂的衰变热量超过SiC组分的衰减热量。