首页> 外文会议>International Power Electronics and Motion Control Conference >Initial voltage angle detection method of a PWM converter without any grid voltage measurement using conduction state of diodes for smooth starting
【24h】

Initial voltage angle detection method of a PWM converter without any grid voltage measurement using conduction state of diodes for smooth starting

机译:PWM转换器的初始电压角检测方法,无需使用二极管的传导状态,无任何网格电压测量,用于平滑起动

获取原文

摘要

Accurate detection of the grid angle at the startup of a converter prevents the over-current trip and also reduces the commissioning time of the system. This paper presents a method to detect initial angle of the grid voltages by measuring the phase currents depending on conduction state of diodes. During the diode conduction, the source voltages are estimated and the estimated voltages are fed into phase locked loop (PLL). When all the diodes are turned off, the source voltage estimator and the PLL are bypassed and the voltage angle is calculated from the frequency of the estimated voltages. The feasibility of the proposed method has been verified by computer simulation and experimental results.
机译:准确检测转换器启动时的网格角可防止过电流跳闸,并降低了系统的调试时间。本文通过根据二极管的导通状态测量相电流来检测电流电压的初始角度的方法。在二极管传导期间,估计源电压并将估计的电压馈入相位锁定环(PLL)。当所有二极管关闭时,绕过源电压估计器和PLL,并且从估计电压的频率计算电压角。通过计算机模拟和实验结果验证了所提出的方法的可行性。