首页> 外文会议>Japan-Korea symposium on nuclear thermal hydraulics and safety >RELAP5 Analysis on the Safety Depressurization and Vent System Transient
【24h】

RELAP5 Analysis on the Safety Depressurization and Vent System Transient

机译:RETAP5安全减压和排气系统瞬态的分析

获取原文

摘要

This study developed the analysis model for RELAP5 by comparison with experimental data. In the development of RELAP5 analysis model, a few adjustments were taken. Thus, the water level was increased for the good agreement of the rate of pressure decrease, and the manipulation of valve also adjusted for the good agreement of the minute behavior in earlier transient. This model was applied to prototypic transient and air clearing. In the analysis of prototypic SDVS transient of KNGR, the rate of pressure decrease in pressurizer was revealed to be 0.2875 MPa/sec, which is faster than the above experimental data, and the pressure of sparger was about 4 MPa. In the application to air clearing transient, the duration time of air clearing of which experiment will be conducted was revealed to be 1 second, and the maximum pressure at the sparger was turned out to be 0.6 MPa at the end of air clearing.
机译:本研究通过与实验数据进行比较开发了RETAP5的分析模型。在RETAP5分析模型的发展中,采取了一些调整。因此,对于压力率的良好一致性,水位增加了水位,并且阀门的操纵也调整了早期瞬态的微小行为的良好一致性。该模型应用于原型瞬态和空气清除。在对KngR的原型SDVS瞬态的分析中,压力剂的压力降低率为0.2875MPa / sec,其比上述实验数据快,并且喷射器的压力约为4MPa。在空气清除瞬态的应用中,将进行实验的空气清除的持续时间被揭示为1秒,并且在空气清除结束时,喷射器的最大压力在0.6MPa。