首页> 外文会议>Japan-Korea symposium on nuclear thermal hydraulics and safety >NUMERICAL EVALUATION OF THE FIVE SENSOR PROBE METHOD FOR MEASUREMENT OF LOCAL INTERFACIAL AREA CONCENTRATION OF CAP BUBBLES
【24h】

NUMERICAL EVALUATION OF THE FIVE SENSOR PROBE METHOD FOR MEASUREMENT OF LOCAL INTERFACIAL AREA CONCENTRATION OF CAP BUBBLES

机译:五种传感器探头测量封面泡沫局部界面浓度的数值评价

获取原文

摘要

The interfacial area concentration (IAC) is one of the most important parameters in the two-fluid model for two-phase flow analysis. The IAC can be measured by a local conductivity probe method that uses the difference of conductivity between water and air/steam. The number of sensors in the conductivity probe may be differently chosen by considering the flow regime of two-phase flow. The four sensor conductivity probe method predicts the IAC without any assumptions of the bubble shape. The local IAC can be obtained by measuring the three dimensional velocity vector elements at the measuring point, and the directional cosines of the sensors. The five sensor conductivity probe method proposed in this study is based on the four sensor probe method. With the five sensor probe, the local IAC for a given referred measuring area of the probe can be predicted more exactly. In this paper, the mathematical approach of the five sensor probe method for measuring the IAC is described, and a numerical simulation is carried out for ideal cap bubbles of which the sizes and locations are determined by a random number generator.
机译:界面区域浓度(IAC)是两相流程分析的双流体模型中最重要的参数之一。 IAC可以通过局部电导率探针方法测量,该方法使用水和空气/蒸汽之间的导电性差异。通过考虑两相流的流动状态,可以根据不同的流动制度来不同地选择电导率探针中的传感器的数量。四个传感器电导率探针方法预测IAC而没有气泡形状的任何假设。可以通过测量测量点处的三维速度矢量元件和传感器的方向余弦来获得局部IAC。本研究提出的五种传感器电导率探针方法基于四个传感器探头方法。利用五个传感器探头,可以更准确地预测探针的给定参考测量区域的局部IAC。在本文中,描述了用于测量IAC的五种传感器探针方法的数学方法,并且对理想帽气泡进行数值模拟,其中尺寸和位置由随机数发生器确定。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号