Performance tests on impulse measuring systems at ultra high voltage research laboratory

机译:超高压研究实验室脉冲测量系统的性能测试

获取原文

摘要

The paper presents procedures adopted for the calibration of measuring systems to ensure their use in impulse tests. Different tests were conducted on the measuring systems for qualifying the testing laboratory as possessing Approved Measuring System (AMS) for recognition of the formal competence to perform certain HV tests. In the absence of the Reference Measuring System (RMS), wherein both dynamic response and scale factors are determined together, alternative methods as proposed in IEC 60-2 were used for qualifying the measuring system as Approved Measuring System, the results of which are presented in the paper. The results of pulse calibration of digital recorders are also presented in this paper to establish the test facility to perform tests on equipments in compliance with the international standards. Some of the limitations in the calibration of systems for high voltage measurements are also described.
机译:本文提出了用于校准测量系统的程序,以确保其在脉冲测试中使用。在测量系统上进行了不同的测试,以使测试实验室具有批准的测量系统(AMS),以识别正式的能力来执行某些HV测试。在没有参考测量系统(RMS)的情况下,其中既有动态响应和缩放因子都是一起确定的,如IEC 60-2所提出的替代方法用于限定测量系统作为批准的测量系统,其结果呈现在论文中。本文还提出了数字记录仪的脉冲校准的结果,以建立测试设施,以符合国际标准的设备进行测试。还描述了用于高压测量系统的系统校准的一些限制。