This paper reports results with the new sensitivity verification for ultra high frequency (UHF) partial discharge (PD) detection applied to three-phase SF/sub 6/ gas-insulated substations (GIS) for rated voltages up to 170 kV. The procedure was developed by CIGRE WG 15/33.03.05. The aim is to examine the practical use of the proposed procedure and to investigate its extension to an unconventional sensor type. UHF PD measurements were carried out on a typical GIS section via potential grading electrodes. Derived results demonstrate the ability of these already built-in devices to serve as UHF sensors, to replace additional sensors sufficiently, and to make further design efforts unnecessary, if UHF diagnostics are required. Measurements, the experimental setup and the adequate test-vessel are described. The sensitivity of the new sensor is compared to the sensitivity of the IEC 60270 method and to other UHF sensors. Results concerning the detection of characteristic defects demonstrate the sensitivity of the new sensor arrangement.
机译:本文报告了对超高频(UHF)局部放电(PD)检测的新灵敏度验证,施加到三相SF / SUB 6 /气体绝缘变电站(GIS),额定电压高达170 kV。该程序由CIGRE WG 15 / 33.03.05开发。目的是检查所提出的程序的实际用途,并调查其对非传统传感器类型的延伸。通过电位分级电极在典型的GIS部分上进行UHF PD测量。派生结果证明了这些已经内置设备用作UHF传感器的能力,以充分替换额外的传感器,如果需要UHF诊断,则不需要进一步设计工作。描述了测量,实验设置和足够的测试容器。将新传感器的灵敏度与IEC 60270方法和其他UHF传感器的灵敏度进行比较。关于检测特征缺陷的结果证明了新传感器布置的灵敏度。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号