首页> 外文会议>International Conference on Electronic Measurement and Instruments >Hydrocracking Air Coolers Real-time Diagnosis System Development Based on Failure Analysis of Flow induced Corrosion
【24h】

Hydrocracking Air Coolers Real-time Diagnosis System Development Based on Failure Analysis of Flow induced Corrosion

机译:加氢裂化空气冷却器基于流动诱导腐蚀的失效分析实时诊断系统开发

获取原文

摘要

The frequent flow induced corrosion of hydrocracking air cooler system always results in a significant economic loss of the petroleum enterprise. Aimed at the issue, the design of hydrocracking air coolers real-time system is completed on the basis of the frame of the corrosion control system. Aspen Plus software is embedded in the system for the modeling and simulation of the corresponding parameters. The databases of the distribute control system (DCS) and laboratory information management system (LIMS) of the hydrocracking plant are linked with the software to the further calculation, monitoring and management. The corresponding anti-corrosion methodology is put forward according to the specific running situation, which can optimize the service operation and enhance the security of the hydrocracking air coolers system essentially.
机译:频繁流动诱导的加氢裂化空气冷却器系统的腐蚀总是导致石油企业的重大经济损失。针对该问题,基于腐蚀控制系统的框架完成了加氢裂化空气冷却器的设计实时系统。 ASPEN Plus软件嵌入在系统中,以进行相应参数的建模和模拟。加氢裂化装置的分布式控制系统(DCS)和实验室信息管理系统(LIMS)的数据库与软件连接到进一步的计算,监控和管理。根据具体的运行情况提出了相应的防腐蚀方法,该方法可以优化服务运行,并基本上提高加氢裂化空气冷却器系统的安全性。