摘要

Fire protection strategies are designed and installed to perform specific functions. For example, a fire sprinkler system is expected to control or extinguish fires. To accomplish this, the system sprinklers must open, and the required amount of water to achieve control or extinguishment must be delivered to the fire location. A fire detection system is intended to provide sufficient early warning of a fire for occupant notification and escape, fire service notification, and in some case activation of other fire protection features (e.g., special extinguishing systems, smoke managmenet systems). Both system activation (detection) and notification (alarm) must occur to achieve early warning. Construction compartmentation is generally designed to limit the extent of fire spread as well as to maintain the building's structural integrity as well as tenability along escape routes for some specified period of time. In order to accomplish this, the construction features must be fire "rated" (based on standard tests) and the integrity of the features maintained.
机译:设计和安装防火策略以执行特定功能。例如,预计消防喷水灭火系统将控制或熄灭火灾。为此,系统喷头必须打开,并且必须将所需的水量达到控制或熄灭。火灾探测系统旨在为乘员通知和逃生,消防服务通知以及其他灭火功能的某些情况激活提供足够的火灾预警(例如,特殊灭火系统,烟雾管理系统)。必须发生系统激活(检测)和通知(警报)以实现预警。施工隔间通常旨在限制火灾的程度,以及维持建筑物的结构完整性以及沿着逃生路线的逃逸路线的折损性。为了实现这一目标,施工功能必须是Fire“评级”(基于标准测试),并且所保持的功能的完整性。