Based on the equation of the mass conservation, a method of relative error analysis is presented in this paper. The two-dimensional and three-dimensional PIV data in the impeller and volute of the centrifugal pump are evaluated by this method. The maximum relative errors of two-dimensional flow fields in the impeller and volute are 2.85% and 10.50% respectively, which of three-dimensional are 3.41% and 2.59% respectively. It indicates that there is acceptable accuracy of the relative error using two-dimensional PIV to measure the flow fields in the impeller. Axial direction velocity can not be neglected near the outlet of the rotating impeller in the volute and the flow fields must be measured by three-dimensional PIV to obtain the reliable experimental data.
机译:基于大规模保护的等式,本文提出了一种相对误差分析的方法。通过该方法评估离心泵的叶轮和蜗壳中的二维和三维PIV数据。叶轮和蜗壳中的二维流场的最大相对误差分别为2.85%和10.50%,三维分别为3.41%和2.59%。它表示使用二维PIV的相对误差的可接受精度来测量叶轮中的流场。在旋转叶轮的出口附近,轴向方向速度在蜗壳中的出口附近,必须通过三维PIV测量流场以获得可靠的实验数据。