首页> 外文会议>Conference on Electrical Insulation and Dielectric Phenomena >Deterioration of silicone rubber for polymer insulators corona discharge and effect of fillers
【24h】

Deterioration of silicone rubber for polymer insulators corona discharge and effect of fillers

机译:用于聚合物绝缘子的硅橡胶的劣化电晕放电和填料的作用

获取原文

摘要

This paper describes deterioration phenomena and mechanisms on silicone rubber housings of the polymer insulators by corona discharges. The corona discharge was observed on the trunk portion the insulator tested in a fog chamber. Nitric acid andozone generated by the corona discharge were recognized on that trunk portion, which was discolored and became whitish. The discolored area was expanded with test period. Surface conditions and mechanical properties of six kinds of the silicone rubbercontaining ATH (Alumina Tri-Hydrate) and CaCO{sub}3 (Calcium Carbonate) as fillers, were investigated after immersion in 1N nitric acid for 96 hours.As a result, weight loss of test pieces containing CaCO{sub}3 and ATH fillers was more than those solely containing ATH. Cracks were observed on the surface of two specimens containing CaCO{sub}3 filler, and not observed on that not containing CaCO{sub}3 filler. This shows the cracks on the surface due to corona discharges are depending on the kind of the filler. The careful survey on the deterioration of the housing rubber due to the corona discharge should be done when we select the housing materialsfor the polymer insulators.
机译:本文通过电晕放电描述了聚合物绝缘体硅橡胶壳体上的劣化现象和机制。在雾腔中测试的绝缘体上观察到电晕放电。由电晕放电产生的硝酸和唑酮在该躯干部分上被识别,这变色并变为发白。变色区域随着测试期扩大。在浸泡在1N硝酸浸泡96小时后,研究了六种硅橡胶的表面条件和氧化铝三水合物)和Caco {sub} 3(碳酸钙)作为填料的填料。结果,减肥含有Caco {sub} 3和Athers的试验片比单独含有Ath的那些。在含有Caco {Sub} 3填料的两个样品的表面上观察到裂缝,并且在不含有Caco {Sub} 3填料的情况下未观察到。这显示了由于电晕放电引起的表面上的裂缝取决于填充物的种类。当我们选择聚合物绝缘体的外壳材料时,应对电晕放电造成仔细调查。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号