首页> 外文会议>IEEE Industry Applications Conference >Connection of frequency-dependent load and fast-rise voltage by power transmission line
【24h】

Connection of frequency-dependent load and fast-rise voltage by power transmission line

机译:通过电力传输线连接频率相关的负载和快速上升电压

获取原文

摘要

This paper investigates the electromagnetics-based transmission-line effects occurring in systems consisting of fast rising voltage sources such as PWM inverters, electromagnetic loads such as electric machines, and long cables interconnecting them. The frequency dependence of the transmission line can only be neglected for sufficiently high frequencies. The frequency dependency of the inverter output impedance, the transmission line's characteristic impedance, and the electric machine's input impedance are investigated and a frequency-dependent model is presented for the system. It is shown that phenomenologically this model corresponds well with measurements made on a practical single-phase system.
机译:本文研究了在由快速上升电压源组成的系统中发生的基于电磁的传输线效应,例如PWM逆变器,电磁负载,例如电机,长电缆互连它们。传输线的频率依赖性只能忽略足够高的频率。研究了逆变器输出阻抗,传输线的特性阻抗和电机的输入阻抗的频率依赖性,并且为系统提供了频率相关的模型。结果表明,这种模型对应于在实际单相系统上进行的测量来良好。