首页> 外文会议>International Power Modulator Symposium >Investigation of Dielectric Flashover in an SF6 Filled Laser Triggered Gas Switch
【24h】

Investigation of Dielectric Flashover in an SF6 Filled Laser Triggered Gas Switch

机译:SF6填充激光触发气体开关中电介质闪络的研究

获取原文

摘要

A study of dielectric flashover in SF6 in a laser triggered gas switch (LTGS) is reported. Flashover occurring on the inside of the insulating barrier of the switch leading to the eventual failure of the switch was studied. The University of Missouri-terawatt test stand is testing the trigger section of a LTGS to understand and improve the flashover characteristics of these switches. A Rimfire LTGS was modified to operate with a trigger gap voltage of 938 kV. The modified switch was tested repeatedly over a range of pressures to examine the sensitivity of switch flashover to several parameters. The aspects of the switch that were tested include triple points both due to asymmetrical torque on the endplates, and due to gaps between the insulator and endplate, and the effect of slower voltage risetime. An analysis of the early findings of this study is presented
机译:报道了一种在激光触发的气体开关(LTGS)中SF 6 中的电介质闪络的研究。研究了在开关的绝缘屏障内部发生的闪络,导致开关的最终故障。密苏里州大川大学试验台正在测试LTG的触发部分以了解和提高这些交换机的闪络特性。修改了RIMFIRE LTGS以使触发间隙电压为938 kV。在一系列压力下重复测试改进的开关,以检查开关闪光灯到几个参数的灵敏度。测试的开关的各个方面包括由于端板上的不对称扭矩而导致的三重点,并且由于绝缘体和端板之间的间隙,以及较慢的电压升空之间的效果。提出了对本研究早期发现的分析

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有