首页> 外文会议>IEEE frequency control symposium >Experimental frequency and phase stability of the hydrogen maser standard output as affected by cavity auto-tuning
【24h】

Experimental frequency and phase stability of the hydrogen maser standard output as affected by cavity auto-tuning

机译:受腔自动调谐影响的氢气波纹标准输出的实验频率和相位稳定性

获取原文

摘要

An atomic hydrogen maser cavity autotuner system and the effect of autotuning on the time and frequency domain stability are described. Measurements of very-long-term stability and drift of the masers were made at several international standards laboratories. Time and frequency domain measurements made at STSC are discussed. The data show that the spectral purity of the maser output signal and the time domain stability are not significantly degraded by cavity frequency-switching; the autotuned maser retains the exceptional short- and medium-term stability of the classical active oscillator maser. Cavity pulling is under precise control, and the exceptional long-term stability capability of the maser can be attained with a single, field operable standard.
机译:描述了原子氢气喷雾腔自动箱系统和自动传递对时间和频域稳定性的影响。在若干国际标准实验室制定了对摩托车的非常长期稳定性和漂移的测量。讨论了在STSC中进行的时间和频域测量。数据表明,腔频率切换的频谱纯度和时域稳定性的光谱纯度不会显着降低;自动避险的蒙皮保留了经典活性振荡器蒙皮的特殊短期和中期稳定性。腔拉动处于精确控制,并且可以通过单个现场可操作的标准实现蒙皮的特殊长期稳定性能力。