In order to improve the reliability and efficiency of high-voltage power converters using series-connected power transistors, a novel method for series connection of power transistors has been proposed, simulated, and studied experimentally. This method has the following advantage compared with conventional methods: the snubber losses and switching times can be reduced by minimizing the value of snubber capacitors: the number of connected devices is not limited; the method is unrelated to the sequence of turn-off; and the circuit is relatively simple. This novel switching algorithm for series connection is able to implement not only dynamic voltage balancing despite the difference of switching characteristics but also the minimization of the value of the snubber capacitor by the Miller effect.
机译:为了提高使用串联电源晶体管的高压功率转换器的可靠性和效率,已经提出了一种新颖的电力晶体管连接方法,并实验研究。该方法与常规方法相比具有以下优势:通过最小化缓冲电容器的值,可以减少缓冲损耗和切换时间:连接器件的数量不受限制;该方法与关断序列无关;电路相对简单。这种用于串联连接的新型切换算法不仅能够实现动态电压平衡,尽管切换特性的差异,但是通过米勒效应最小化缓冲电容的值。