首页> 外文会议>IEEE Conference on Decision and Control >A Hankel singular value approach for identification of low level dynamics in flexible structures
【24h】

A Hankel singular value approach for identification of low level dynamics in flexible structures

机译:一种智能结构识别低电平动态的胃奇异价值方法

获取原文
获取外文期刊封面目录资料

摘要

The intensity of dynamics in a flexible structure is characterized by its Hankel singular values. Low level dynamics may be caused by generic properties of a structure or by its actuator and sensor configurations. In the latter case, it is shown that the dynamics can significantly be amplified by small perturbations of actuator and/or sensor configurations. In the presented examples, the variations of sensor configuration of 0.05 or less caused an increase of Hankel singular values of order 1000. This approach is useful for model reduction and model order determination in the presence of noise.
机译:柔性结构中的动态强度的特征在于其嗜肝奇异值。低电平动态可能是由结构的通用性质或其执行器和传感器配置引起的。在后一种情况下,示出了通过致动器和/或传感器配置的小扰动显着放大动力学。在所呈现的示例中,传感器配置的变化为0.05或更小导致顺序1000的Hankel奇异值的增加。该方法对于噪声存在的模型减少和模型顺序确定是有用的。