首页> 外文会议>Intersociety Energy Conversion Engineering Conference >The effects of nonlinear loading upon the Space Station Freedom 20 kHz power system
【24h】

The effects of nonlinear loading upon the Space Station Freedom 20 kHz power system

机译:非线性负荷对空间站自由20kHz电力系统的影响

获取原文
获取外文期刊封面目录资料

摘要

The Space Station Freedom power distribution system, which consists of dual redundant 20 kHz, 440 V RMS, single-phase power systems, is discussed. The effect of a typical space station nonlinear load on the measurement of RMS current and voltage at various points in the Space Station power system has been investigated using the Electromagnetic Transients Program (EMTP). The load current distortion at the user interface, its effect on the distribution system, and its relationship to power factor have been studied. Modeling results are compared to test data. The differences under nonlinear loading are evaluated and presented as a measure of distribution voltage distortion and current measurement accuracy.
机译:讨论了空间站自由配电系统,该配电系统由双冗余20kHz,440V rms,单相电力系统组成。使用电磁瞬变程序(EMTP)研究了典型的空间站非线性负荷对空间站电力系统中各个点处的RMS电流和电压的测量。已经研究了用户界面处的负载电流失真,其对分布系统的影响及其与功率因数的关系。建模结果与测试数据进行比较。评估非线性加载下的差异,并呈现为分配电压失真和电流测量精度的量度。