首页> 外文会议>IEEE Ultrasonics Symposium >Measurement Model for Attenuation of Leaky Surface Acoustic Waves by the Line-Focus-Beam Ultrasonic Material Characterization System
【24h】

Measurement Model for Attenuation of Leaky Surface Acoustic Waves by the Line-Focus-Beam Ultrasonic Material Characterization System

机译:线聚焦光束超声材料表征系统泄漏表面声波衰减测量模型

获取原文

摘要

We experimentally and theoretically studied an exact measurement model for attenuation of leaky surface acoustic waves (LSAWs) using the line-focus-beam ultrasonic-material-characterization (LFB-UMC) system. We measured the LSAW propagation characteristics (viz., phase velocity and attenuation) for two specimens of synthetic silica (SiO_(2)) glass and borosilicate (Pyrex) glass at 225 MHz. We detected acoustic loss of LSAWs due to the acoustic absorption effect for the Pyrex glass by calibrating the measurement results with reference to those of the SiO_(2) glass.
机译:我们通过线 - 聚焦光束超声波材料表征(LFB-UMC)系统进行了实验和理论地研究了用于衰减漏漏的表面声波(LSAW)的精确测量模型。我们测量了在225MHz的两种合成二氧化硅(SiO_(2))玻璃和硼硅酸盐(Pyrex)玻璃的两个标本的锯展宣传特性(viz,相速度和衰减)。通过参考SiO_(2)玻璃的那些,我们通过校准测量结果来检测声解s的声学损失,因为Pyrex玻璃校准测量结果。