This paper demonstrates an easy-to-use dual-function biosensor for real-time monitoring of drug-induced cardiac toxicity screening, by measuring both electrophysiology and mechanophysiology of drug-treated cardiomyocytes simultaneously. The proposed biosensor consists of a photosensitive polymer cantilever on which microelectrodes are patterned. Electrophysiology is measured by recording field potential using microelectrode array (MEA), and contractile motion is measured using cantilever deflection upon culturing of cardiomyocytes. This dual-function biosensor has been tested for its reliability for drug screening by adding Verapamil to the cell culture and assessing the outputs in synchrony. Field potential duration (FPD) reduced on increasing concentration (IC50=166.2 nM), as did contraction force (IC50=242.9 nM). This biosensor is a reliable next-generation device of drug toxicity screening.
机译:本文通过同时测量药物治疗的心肌细胞的电生理学和机械学,易于使用的双功能生物传感器,用于实时监测药物诱导的心肌毒性筛选。所提出的生物传感器由光敏聚合物悬臂组成,图案化了微电极。通过使用微电极阵列(MEA)记录现场电位来测量电生理学,并且在培养心肌细胞时使用悬臂偏转测量收缩运动。通过向细胞培养添加维拉帕米并评估同步的输出来测试这种双功能生物传感器的可靠性。降低浓度的潜在持续时间(FPD)减少(IC 50 = 166.2nm),收缩力量(IC 50 = 242.9 nm)。这种生物传感器是一种可靠的下一代药物毒性筛选装置。