Single conductor insulation of high voltage machines using mica tapes

机译:使用MICA磁带的高压机器单导体绝缘

获取原文

摘要

In the last few years considerable improvments of insulation techniques in high voltage machines have been achieved by the introduction of mica tape enameled copper bars. With respect to corona and thermal resistance requirements mica has shown to be the most suitable insulating material. Various mica tapes * are made of polyester film as a substrate, mica paper and a modified epoxy resin as a binder, which keeps the tapes flexible even after a longer treatment with high temperatures. In a typical case the breakdown voltage between turns of wires after 1000 hours thermal ageing at 180??C has dropped from 8 kV to only 6 kV at minimum and after 1 million hours thermal ageing at this temperature a MICALASTIC?? insulated coil** shows still a breakdown voltage of 4,2 kV.
机译:在过去的几年中,通过引入云母带搪瓷铜棒实现了高压机中的绝缘技术的大大改善。关于电晕和热阻要求云母已显示为最合适的绝缘材料。各种云母胶带*由聚酯薄膜作为基材,云母纸和改性环氧树脂作为粘合剂制成,即使在用高温处理较长的处理后,也可以使带胶带柔性。在典型的情况下,在180小时的1000小时后导线之间的击穿电压在180℃下的热老化至少从8kV掉落到仅6kV,最小和100万小时在此温度下热老化脊髓旋转?绝缘线圈**显示仍然是4,2 kV的击穿电压。