Pollution flashover will occur when the natural pollution of insulators on transmission lines reaches to a certain extent, resulting in pollution flashover accidents. Therefore, the analysis of natural pollution characteristics of insulators is of great significance to prevent the occurrence of pollution flashover. Based on equivalent salt deposit density (ESDD) and microscopic particle image analysis, the natural accumulation characteristics and test analysis of XP-70 type porcelain insulator is presented in this paper. The results show that the effect of insulator contamination is mainly reflected in wet sedimentation caused by gravity, in which the air humidity plays an important role, and the lower surface remains affected. The pollution severity has a significant influence on the natural pollution characteristics of the upper surface of insulator, but it has little impact on the lower surface. The particle size decreases with the increase of fouling time, increase of ESDD and the aggravation of pollution making the bottom surface is slightly different.
机译:当输电线路上的绝缘体的自然污染到达一定程度时,将发生污染闪络,导致污染百万发事故。因此,分析绝缘体的天然污染特征是具有重要意义,以防止污染闪络的发生。基于等效耐盐密度(ESDD)和微观粒子图像分析,本文提出了XP-70型瓷绝缘子的自然堆积特性和试验分析。结果表明,绝缘体污染的效果主要反映在由重力引起的湿沉降中,其中空气湿度起到重要作用,下表面仍然受到影响。污染严重程度对绝缘体的上表面的天然污染特性产生了重大影响,但它对下表面影响很小。粒度随着污垢时间的增加而降低,ESDD的增加和使底表面的污染加剧略有不同。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号