首页> 外文会议>International Conference on Nuclear Engineering >VIBRATION ALARM ANALYSIS AND TREATMENT OF MAIN COOLANT PUMP IN NUCLEAR POWER PLANT
【24h】

VIBRATION ALARM ANALYSIS AND TREATMENT OF MAIN COOLANT PUMP IN NUCLEAR POWER PLANT

机译:核电站主冷泵振动报警分析及处理

获取原文

摘要

The structure of main coolant pump in a nuclear power plant and vibration alarm are introduced. Vibration analysis and trouble diagnosis have been carried out. It shows that pump shaft vibration is mainly composed of running frequency (1×) and half of running frequency (0.5×), motor shaft vibration is just composed of 1×. The vibration fluctuation in pump shaft is caused by the variation of amplitude in 0.5×. Based on vibration analysis result, the fault investigation has been launched, in which it includes installment, measurement, dynamic balance and pump design. After detailed investigation, the excessive vibration was induced by the dynamic unbalance of pump shaft and unsteady vortex of shaft seal water. The research for treatment has been implemented on dynamic balance and seal water flow. It is suggested to increase the seal water flow to control vibration fluctuation. The result shows that this method is effective, economical, safe, and very easy to implement for suppressing flash vibration alarm.
机译:介绍了核电厂和振动报警器中主冷却液泵的结构。已经进行了振动分析和故障诊断。它表明,泵轴振动主要由运行频率(1×)和运行频率(0.5×)的一半组成,电机轴振动恰好由1×组成。泵轴中的振动波动是由0.5倍的振幅的变化引起的。基于振动分析结果,已经启动了故障调查,其中包括分期付款,测量,动态平衡和泵设计。经过详细的调查,通过泵轴和轴密封水的不稳定涡流的动态不平衡引起过度振动。治疗研究已经在动态平衡和密封水流上实施。建议增加密封水流以控制振动波动。结果表明,该方法是有效的,经济,安全,非常易于抑制闪光报警器。