This paper researched the behavior of 20mm break Loss of Coolant Accident (LOCA) which is located in the Direct Vessel Injection (DVI) line of the integrated small modular reactor (SMR) in case of full power with RELAP5-3KEYMASTER simulation system. The response of passive safety systems is analyzed and compared with the Primary Safety Analysis Report (PSAR) post-accident. Tendency for the variation of main parameters after the accident agree well with the PSAR, which validates the accuracy and rationality of the model, and solves the new problems in the process of modeling and provides an important tool for the research and development of SMR. Cooling and depressurization are calculated post-accident. The variation of main parameters post-accident and the accident advancement and results have been analyzed. Operation intervention is given and the effects with it are discussed. And the emergency strategy for development and verification of Emergency Operating Procedures (EOP) is given.
机译:本文研究了冷却液事故(LOCA)的20毫米断裂损失的行为,其位于集成的小型模块化反应器(SMR)的直接船舶注射(DVI)线(SMR)的情况下,具有RETAP5-3KEYMAST仿真系统。分析了被动安全系统的响应,并与事故发生后的主要安全性分析报告(PSAR)进行了比较。事故发生后主要参数变化的趋势与PSAR吻合良好,这验证了模型的准确性和合理性,并解决了建模过程中的新问题,并为SMR进行了研究和开发提供了重要的工具。在事故发生后计算冷却和减压。分析了事故后主要参数的变化以及事故进步和结果。给出了操作干预,并讨论了它的效果。给出了紧急操作程序(EOP)的开发和验证的紧急策略。