During a severe accident of a nuclear reactor, radioactive aerosols may be released from degraded nuclear fuels. Pool scrubbing is one of the efficient filters with a high aerosol removal efficiency, in other words a high decontamination factor (DF). Because of its high performance, many pool scrubbing experiments have been performed and several pool scrubbing models have been proposed. In the existing pool scrubbing experiments, an experimental condition of aerosol number concentration was seldom taken into account. It is probably because DF is assumed to be independent of aerosol number concentration, at least, in the concentration where aerosol coagulation is limited. The existing pool scrubbing models also follow this assumption. In order to verify this assumption, we performed a pool scrubbing experiment with different aerosol number concentrations under the same boundary conditions. The test section is a transparent polycarbonate pipe with an inner diameter of 0.2 m. 0.5 μm SiO_2 particles were used as aerosols. As a result, DF was increasing as decreasing the aerosol number concentration. In order to ensure a reliability of this result, three validation tests were performed with meticulous care. According to the results of these validation tests, it was indicated that DF dependence on the aerosol concentration was not because of our experimental system error including measurement instruments but a real phenomenon of the pool scrubbing.
机译:在核反应堆的严重事故中,放射性气溶胶可能从降解的核燃料中释放。泳池擦洗是气溶胶去除效率高的有效滤光器之一,换句话说是高净化因子(DF)。由于其高性能,已经进行了许多池擦洗实验,并且已经提出了几种池擦洗模型。在现有的池擦洗实验中,很少考虑气溶胶数浓度的实验条件。它可能是因为假设DF独立于气溶胶数浓度,至少在气溶胶凝结受限的浓度中。现有的池擦洗模型也遵循此假设。为了验证这种假设,我们在相同的边界条件下进行了具有不同气溶胶数浓度的池擦洗实验。试验部分是透明聚碳酸酯管,内径为0.2米。将0.5μmsiO_2颗粒用作气溶胶。结果,DF随着降低气溶胶数浓度而增加。为了确保这种结果的可靠性,用细致的护理进行三次验证测试。根据这些验证测试的结果,表明DF对气溶胶浓度的DF依赖性不是因为我们的实验系统误差,包括测量仪器,而是池擦洗的真正现象。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号