首页> 外文会议>International Conference on Nuclear Engineering >FAILURE ANALYSIS AND STRATEGY INVESTIGATION OF THE RUPTURE ON THE GLAND SEAL STEAM DRAIN PIPELINE OF THE REHEAT STOP VALVE
【24h】

FAILURE ANALYSIS AND STRATEGY INVESTIGATION OF THE RUPTURE ON THE GLAND SEAL STEAM DRAIN PIPELINE OF THE REHEAT STOP VALVE

机译:重新清除止动阀腺密封蒸汽排水管道破裂的故障分析与策略调查

获取原文

摘要

Macroscopical inspection and analysis of the pipe component, microstructure, fracture and corrosion product were conducted on the pipe parent metal, heat affected zone and the weld zone of the ruptured reheat stop valve shaft seal steam pipe of Qinshan III. The main failure cause could be concluded that oxidation corrosion on the pipe inner surface near the valve with high temperature steam cause the wall thickness largely reduced, and corrosion fatigue due to pipeline vibration eventually lead to fracture. The thinning rate of the failure pipe is assessed. There are total 32 similar pipelines in the two units of Qinshan III. The preventive repair strategies for this kind of pipelines are investigated. Wall thickness measurement and evaluation should be conducted in the outage sixth years after the pipeline replacement. The inspection location is 30mm~150mm extent downstream of reheat stop valve outlet nozzle. The pipe section should be replaced in accordingly outage when the minimum measured wall thickness is less than 2mm.
机译:管母金属,热影响区和秦山三件破裂再欣拔阀轴密封蒸汽管的管母金属,热影响区和焊接区进行了宏观检查,微观结构,断裂和腐蚀产物。主要故障原因可以得出结论,在具有高温蒸汽的阀门附近的管道内表面上的氧化腐蚀导致壁厚大大降低,并且由于管道振动引起的腐蚀疲劳最终导致骨折。评估失效管的稀释率。秦山III的两个单位共有32个类似的管道。调查了这种管道的预防性修复策略。墙壁厚度测量和评估应在管道更换后的第六年中停电。检验位置是再热停止阀门出口喷嘴下游30mm〜150mm。当最小测量的壁厚小于2mm时,管区应更换。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号