首页> 外文会议>International Conference on Nuclear Engineering >STUDY ON THE INTERACTION BETWEEN SAFETY-RELATED AND NON SAFETY-RELATED ITEMS IN THE COMPONENT COOLING WATER SYSTEM ROOM OF THE QINSHAN NUCLEAR POWER PLANT IN THE EARTHQUAKE CONDITION
【24h】

STUDY ON THE INTERACTION BETWEEN SAFETY-RELATED AND NON SAFETY-RELATED ITEMS IN THE COMPONENT COOLING WATER SYSTEM ROOM OF THE QINSHAN NUCLEAR POWER PLANT IN THE EARTHQUAKE CONDITION

机译:秦山核电站部件冷却水系统室中安全相关和非安全相关项目在地震条件下的互动研究

获取原文

摘要

Safety-related items in nuclear power plants are now generally placed separately from the non-safety-related items, but it was not strictly required before. Therefore, it is very important to study whether the non-safety-related items will affect the safety-related items when they are dropped down in an earthquake situation, which determines the safety of a nuclear power plant and its future life extension applications. This research was based on the cooling water system room with the safety and non-safety related items installed together, as an example to study whether the non-safety-related items such as vent pipes and DN50 fire fighting pipes arranged above will damage the DN300 pipes and valves arranged below when earthquakes occur. For the experiments, the relative positions of objects in the room was reproduced by 1:1. The pressure-holding performance of the pipe was used as a criterion for the damage. The research results of the experiments show that when the 10-meter-long DN50 pipe was dropped from the position of 8 meters height and the 8-meter-long vent dropped from position of 3.6 meters height, they do not affect the integrity of the DN300 valve and pipe below. After the experiment, pressure drop in two hours for the pipe is less than 0.1%. The main body of the valve does not fail neither. The numerical simulation study also shows that there is no failure phenomenon in the simulation as well. Compared with the test results, the impact acceleration and the vent deformation both have the same trend.
机译:核电站的安全相关项目通常与非安全相关项目分开放置,但之前并不严格要求。因此,研究非安全相关项目是否会在地震情况下跌落时会影响安全相关项目是非常重要的,这决定了核电站的安全性及其未来的生命延期应用。该研究基于冷却水系统室,具有安全和非安全相关项目的安装,作为研究上面排放的非安全相关项目等非安全相关项目是否会损坏DN300在地震发生时下面排列的管道和阀门。对于实验,房间内物体的相对位置被再现为1:1。管道的压力保持性能用作损坏的标准。实验的研究结果表明,当10米长的DN50管道从8米高的位置掉下时,8米长的通风口从3.6米高的位置掉下来,它们不会影响完整性DN300阀门和下面的管道。实验后,管道2小时内的压降小于0.1%。阀门的主体也不会失败。数值模拟研究还表明模拟中没有故障现象。与测试结果相比,影响加速度和排气变形都具有相同的趋势。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号