首页> 外文会议>International Conference on Electrotechnical Complexes and Systems >Research of the Temperature In the Check Valve Zone During Local Induction Heating of Pipeline Valves In the Comsol Multiphysics Application Package
【24h】

Research of the Temperature In the Check Valve Zone During Local Induction Heating of Pipeline Valves In the Comsol Multiphysics Application Package

机译:COMSOL多体应用包装中局部感应加热过程中止回阀区温度的研究

获取原文

摘要

The features of induction local heating of problem areas of pipeline fittings of oil and gas wells containing a check valve to temperatures that do not exceed safe values and provide a specified technological mode of operation of the well are considered. A simulation of thermal processes in the COMSOL Multiphysics application package was performed in order to assess the operability of the check valve at different locations of the induction heater relative to the check valve and different types of inductor used for heating. The simulation results confirm the effectiveness of using induction heating of local zones to maintain the operation of the check valve. It is shown that for a tee valve, the most acceptable is the use of an induction heater located on the annulus line of an oil and gas well, and the most energy-efficient is an induction heater with a local inductor built into the body.
机译:考虑了含有止回阀的油气井的管道配件问题区域的局部局部加热的特点,其温度不超过安全值,并提供了井的指定技术操作模式。执行COMSOL多体型施加包装中的热处理的模拟,以便在感应加热器的不同位置评估止回阀相对于止回阀和用于加热的不同类型的电感器的可操作性。仿真结果证实了使用局部区域的感应加热以维持止回阀操作的有效性。结果表明,对于TEE阀,最可接受的是使用位于油气和气体的环形管线上的感应加热器,并且最节能是具有内置在主体中的局部电感的感应加热器。