In order to develop a grain flow sensor, a test rig was built. Three weighting sensors were mounted on the weighting bin in the test rig to calibrate grain flow sensor and verify the accuracy of grain flow sensor. A valve plate was inserted in the bottom of the feed bin. The feed flow could be controlled by adjusting opening of the valve plate. A weighting measurement model and a feed flow model were established respectively according to user manual and calibration experiments. Weighting accuracy and feed rate for the test rig was analyzed through experiments. Results showed that the maximum relative error of weighting was 1.12%, the minimum relative error was 0.36%, and the average relative error was 0.61%. The average relative error of feed flow ranging from 0.5 to 2.4 kg/s was less than 4%. The test rig developed is stable and reliable, and meets the requirements for development and testing of the grain flow sensor.
机译:为了开发晶粒流量传感器,建造了试验台。三个加权传感器安装在试验台中的加权箱上以校准晶粒流量传感器并验证晶粒流量传感器的准确性。将阀板插入进料箱的底部。进料流可以通过调节阀板的开口来控制。根据用户手册和校准实验分别建立加权测量模型和进料流模型。通过实验分析了试验室的加权精度和进料速率。结果表明,重量的最大相对误差为1.12%,最小相对误差为0.36%,平均相对误差为0.61%。从0.5至2.4kg / s的进料流量的平均相对误差小于4%。开发的试验台稳定可靠,并满足晶粒流量传感器的开发和测试要求。