A triple-coil pulsed magnet aiming at 100 T (Tesla) was developed and tested at the Wuhan National High Magnetic Field Center (WHMFC). The outer coil was powered by a 100 MJ pulse generator and a battery bank connected in series. The middle and inner coils were energized by 25 kV capacitor banks. The magnet failed at 83 T, while the whole structure remained intact. The failure process is analyzed by using the recorded waveforms of the voltage and the current, as well as disassembling and dismantling the failed magnet. It shows that the electrical breakdown occurred between the middle and outer coils as well as within the inner coil, and the inner coil broke down before the middle and outer coils. Based on the previous analysis, the time line of the failure process is given. Additionally, the possible reasons for the failure are also discussed. The results show that the buckling and fiber fracture of the inner coil might cause the accident.
机译:在武汉国家高磁场中心(WHMFC)开发并测试了旨在为100吨(特斯拉)的三线圈脉冲磁铁。外圈由100MJ脉冲发生器和串联连接的电池组供电。中间线圈由25 kV电容器组通电。磁铁在83吨失效,而整个结构保持完整。通过使用电压和电流的记录波形和拆卸和拆卸故障磁体来分析故障过程。它表明,在中间线圈以及内线线圈内发生电击穿,内部线圈在中间线圈和外圈之前崩溃。基于先前的分析,给出了故障过程的时间线。此外,还讨论了失败的可能原因。结果表明,内部线圈的屈曲和纤维骨折可能导致事故。