The accuracy of the arc description of the isolation switch is a key factor affecting the calculation accuracy of the fast transient overvoltage (VFTO). In the current simulation calculation, the commonly used resistance model is equivalent to isolating the switching arc, so that it is impossible to deeply simulate the changes of various state quantities during the arc development process. Therefore, based on the theory of multiple reignition arcs and the theory of segmented arcs, this paper compares and analyzes three equivalent models of isolating switch arcs, and calculates and analyzes the internal VFTO of a gas insulated substation (GIS) in a 550kV power station. It is proved that the model can simulate the physical process of the arc during the operation of the isolating switch more accurately, and it is practical for the numerical calculation and characteristic analysis of VFTO.
机译:隔离开关的电弧描述的准确性是影响快速瞬态过压(VFTO)计算精度的关键因素。在当前的仿真计算中,常用的电阻模型相当于隔离开关弧,因此在电弧开发过程中不可能深深地模拟各种状态量的变化。因此,基于多次重新开始的理论和分段弧理论,本文比较和分析了三等效的隔离开关弧模型,并计算了550kV发电站中的气体绝缘变电站(GIS)的内部VFTO 。事实证明,该模型可以更准确地在隔离开关的操作期间模拟电弧的物理过程,并且对于VFTO的数值计算和特征分析是实用的。