The Analysis of Some Results of Electrical Capacitance and Dissipation Factor Measurements

机译:对电容和耗散因子测量的一些结果分析

获取原文

摘要

This paper is dedicated to the analysis of time series of measured values of electrical capacitance and dissipation factor of shielded and unshielded network cables based on twisted pair. It was shown that in case of applying parallel equivalent scheme of tested object with dielectric power losses the analysis of time series can be complicated by simultaneous increasing of dissipation factor with the increasing of electrical capacitance, as such dependence contradicts the admissible according to the applied equivalent scheme affect of electrical capacitance on measured values of dielectric dissipation factor. In this case difficulties can be caused by possible substantial discrepancy between the mean value of dissipation factor which corresponds to the value of electrical capacitance and the mean value of dissipation factor calculated for the whole array of obtained results of measurements, as such discrepancy causes ambiguity in possible interpretation of obtained results.
机译:本文基于双绞线对屏蔽和非屏蔽网络电缆的电容和耗散因子的测量值的时间序列分析。结果表明,在施加具有介电功率损失的测试物体的并联等效方案的情况下,通过同时增加随着电容的增加来同时增加时间序列的分析,因为这种依赖性根据所施加的等价物的可接受矛盾方案对电容对介电耗散因子测量值的影响。在这种情况下,通过对应于电容的电容值的平均值和对测量结果的整个测量结果的整个阵列计算的耗散因子的平均值之间的平均值之间,可以引起困难。由于这种差异导致歧义可能的解释结果。