首页> 外文会议>Electrical Safety in Hazardous Areas, 1988., Fourth International Conference on >Aspects of temperature rise measurement and temperature protectionof rotating electrical machines, with particular reference to increasedsafety motors and operation at variable speed
【24h】

Aspects of temperature rise measurement and temperature protectionof rotating electrical machines, with particular reference to increasedsafety motors and operation at variable speed

机译:温升测量和温度保护方面旋转电机的数量,尤其是增加安全电动机和变速运行

获取原文

摘要

Guaranteeing that the temperature of apparatus installed in ahazardous area does not rise to a level which would cause ignition ofthe hazardous gas/air mixture is a vital part of all the protectionconcepts. The author reviews some aspects of temperature measurement andcontrol relating to rotating electrical machines. The aspects are lookedat particularly from the point of view of satisfying the certifyingauthority that they are justified in issuing a certificate confirmingcompliance with one of the relevant standards
机译:确保设备中安装的温度 危险区域未升高到会引起起火的水平 有害气体/空气混合物是所有保护措施的重要组成部分 概念。作者回顾了温度测量的一些方面,并 与旋转电机有关的控制。看方面 特别是从满足认证的角度 有权在签发证明书时证明他们是正当的 符合相关标准之一