首页> 外文会议>Electrical Electronics Insulation Conference, 1989. Chicago '89 EEIC/ICWA Exposition., Proceedings of the 19th >A study of corona discharge and surface tracking in theintermediate voltage range 2 to 3 kVAC
【24h】

A study of corona discharge and surface tracking in theintermediate voltage range 2 to 3 kVAC

机译:电晕放电和表面跟踪的研究。中间电压范围2至3 kVAC

获取原文

摘要

Laboratory testing of motorette specimens showed that specimensfailed in a matter of minutes when subjected to test voltages of 2300VAC to 2500 VAC. A study was designed and implemented to determine themode of failure and identify the cause. The author presents the stepstaken, the information learned at each step, and the results of thisevaluation. It was shown that the cause of failure was a combination ofa corona-type discharge and the related surface tracking. A directrelationship was also found between specimen failure and moisture,physical design of the specimen, environment, and applied voltage
机译:摩托车样本的实验室测试表明,这些样本 在经受2300的测试电压后几分钟内发生故障 VAC至2500 VAC。设计并实施了一项研究,以确定 故障模式并找出原因。作者介绍了步骤 ,在每个步骤中学习到的信息以及此操作的结果 评估。结果表明,失败的原因是以下原因的综合原因: 电晕放电和相关的表面跟踪。直接 还发现了样品破坏与湿度之间的关系, 样品的物理设计,环境和施加电压